product

  • Manufacturer for Residual Circuit Current Breaker - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Manufacturer for Residual Circuit Current Breaker - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • 2018 Good Quality Alarm Contacts - Alarm Contacts – DaDa

    2018 Good Quality Alarm Contacts - Alarm Contacts – DaDa

    Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of  circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position     Open position              DAM1-125/160BC       DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A           DZ20-225BC        DZ20-225A               ...
  • Low price for 40 Amp Circuit Breaker - DAB7-63 DC miniature Circuit Breaker – DaDa
  • China New Product 50a Circuit Breaker - DAB6  MCB – DaDa

    China New Product 50a Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • OEM/ODM China Mccb 300 A - DAM1 1600 Series MCCB ABB ISOMAX – DaDa

    OEM/ODM China Mccb 300 A - DAM1 1600 Series MCCB ABB ISOMAX – DaDa

    Advantages • Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. • Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting onto an installation panel. • With the help of special clamp 125 and 160 units can be installed onto a DIN-rail. ...
  • OEM China 30 Amp Circuit Breaker - C45 4P  Miniature Circuit Breaker – DaDa

    OEM China 30 Amp Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • New Arrival China 10 Amp Mini Circuit Breaker - DAB7-63 DC miniature Circuit Breaker – DaDa
  • China Cheap price Miniature circuit breaker - HVS  Isolator – DaDa

    China Cheap price Miniature circuit breaker - HVS Isolator – DaDa

    Low Watt Loss Low power loss. Longer Electrical Life DesIgned for better and longer electrical life. Value for Money Assured reliability and service makes it value for money. Low power consumption, thus cost effective & energy saving Consumes less power, thus cost effective and energy saving.
  • 2018 Good Quality Rcbo Electrical - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    2018 Good Quality Rcbo Electrical - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • OEM/ODM Manufacturer 3 Pole Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    OEM/ODM Manufacturer 3 Pole Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • China Supplier Overload Circuit Breaker - DAB5 MCB – DaDa

    China Supplier Overload Circuit Breaker - DAB5 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • China Cheap price Motor Protection Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    China Cheap price Motor Protection Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...