product

  • China Manufacturer for 63 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    China Manufacturer for 63 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
  • Factory wholesale 150 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Factory wholesale 150 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • China Cheap price Motor Protection Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    China Cheap price Motor Protection Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Manufacturer for Mcb Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Manufacturer for Mcb Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ...
  • 2018 China New Design Main Mccb - DAM1 400 MCCB ABB ISOMAX – DaDa

    2018 China New Design Main Mccb - DAM1 400 MCCB ABB ISOMAX – DaDa

    Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig...
  • 2018 High quality Contactor Switch Ac - Contactor – DaDa

    2018 High quality Contactor Switch Ac - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Good Quality Contactor - Contactor – DaDa

    Good Quality Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Manufacturer for 45a Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Manufacturer for 45a Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • Professional China Leakage circuit breaker - DAM1 -160L  ELCB Earth Leakage protection circuit breaker1 – DaDa

    Professional China Leakage circuit breaker - DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • High Quality Rotary Handle Mechanism - Shunt Release – DaDa

    High Quality Rotary Handle Mechanism - Shunt Release – DaDa

    The shunt release is intended for remote controlling of opera of MCCB Release instantaneous duty. Characteristics of Shunt release: Electricalaccessories Shunt release Range ofsupply voltage (0.7-1.1)) x Us Rated controlsupply voltage us   Power supply AC 50Hz 220V 380V Power loss 150V 150V DC 110V 220V Power loss   150V Wiring diagram of Shunt release: SB2- Opening Push-putton(ready by user ) P3,P4- Terminal number Us- Control power QF -Au...
  • 2018 China New Design MCB switch - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    2018 China New Design MCB switch - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...