Good User Reputation for 125 Amp Circuit Breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
Manufacturer for Mcb Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ... -
High definition 32 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P... -
Wholesale Price China 5 Amp Mini Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
OEM/ODM Supplier Solar Circuit Breaker - HVS MCB circuit breaker – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
Professional Design 10 Amp Mini Circuit Breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
Factory Cheap Hot 10 Amp Mini Fuse Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ... -
2018 Latest Design Electric Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
Newly Arrival Residual Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
Professional China Id Rccb - DAL1-63 Residual Current Circuit Breakers – DaDa
Introduction DAL1-63 residual current circuit breakers are protection equipment which must be used to protect human life against dangerous electric shocks or prevent the fires arising out of isolation mistakes thereby detecting isolation mistakes to occur within the plant in advance. Sigma residual current circuit breakers are produced with 2 and 4 poles in accordance with IEC EN 61008-1 standard and in compliance with CE norms under ISO 9001:2008 quality assurance system. What is the differe... -
Factory Price For Motor Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig... -
Newly Arrival Residual Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...