product

  • Good Quality Earth Leakage Circuit Breaker - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    Good Quality Earth Leakage Circuit Breaker - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • Top Quality interruptor - Micro changeover switch – DaDa

    Top Quality interruptor - Micro changeover switch – DaDa

    l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen...
  • Competitive Price for 400 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Competitive Price for 400 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • Short Lead Time for 4 Pole Mccb Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa

    Short Lead Time for 4 Pole Mccb Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa

    >> Introduction BA47-29  are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui...
  • New Delivery for 60a Circuit Breaker - C45 3P  Miniature Circuit Breaker – DaDa

    New Delivery for 60a Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
  • Free sample for Automatic Circuit Breaker - Micro changeover switch – DaDa

    Free sample for Automatic Circuit Breaker - Micro changeover switch – DaDa

    l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen...
  • OEM/ODM Supplier Solar Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    OEM/ODM Supplier Solar Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • Manufacturing Companies for 15 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    Manufacturing Companies for 15 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
  • Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Special Price for Circuit Breaker Switch - HVS  MCB  with window – DaDa

    Special Price for Circuit Breaker Switch - HVS MCB with window – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of  circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position     Open position              DAM1-125/160BC       DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A           DZ20-225BC        DZ20-225A               ...
  • New Arrival China Industrial circuit breaker – DAM2 Moulded Case Circuit Breaker – DaDa

    New Arrival China Industrial circuit breaker – DAM2 Moulded Case Circuit Breaker – DaDa

    Application DAM2  series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2 circuit ...