-
PriceList for Double Pole Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa
Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t... -
2018 High quality Thermal Shrink Joint Box – MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa
Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product... -
2018 High quality Modular Power Distribution Box – SHPN Series Waterproof Distribution Box – DaDa
Outline Dimension Packing Information SHPN waterproof distribution box Carton L*W*H(cm) (PCS/CTN) G.W.(kgs/ctn) N.W.(kgs/ctn) SH4PN 4 way 510*355*450 30 10 9 SH6PN 6 way 540*355*430 20 16 15 SH9PN 9 way 540*425*465 20 19 18 SH12PN 12 way 595*485*575 20 27 26 SH18PN 18 way 595*485*405 10 19 18 SH24PN 24 way -
2018 Latest Design Electric Circuit Breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
-
Professional China Plug-In Device And Draw-Out Device - Plug-In And Draw-Out Device – DaDa
CM 1 Plug-in Version Accessory Type Scope of application Specification and quantities Contact pin Arc-isolation plate and quantities Plug-in version install using hexagonal screw and quantities Circuit breaker install using screw and quantities Contact pin fixed screw and quantities User bind the board install using screw and quantities 63 Type plug-in version CM1-63,NM1-63,CDM1-63,TM30-63 1 6 4 4-M6X23 4-M3X18 6-M5copper nut 6-M5X10 100 Type plug-... -
Manufacturer for Ac Dc Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3) -
Hot sale Two Pole Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co... -
Short Lead Time for 4 Pole Mccb Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
China Supplier Overload Circuit Breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
High Quality Electronic Mccb - CM1E Electronic MCCB – DaDa
Introduction DAM2E CM1 Electronic adjustable moulded case circuit breaker has three protection function, the circuit breaker with utilization category B connected with other short-circuit protection device in the same circuit has completely optional under short circuit circumstance; With five tripping features, the user can set the equipment through the shunt release according to the load current, electronic shunt release is powered by circuit breaker itself; current signal and control power ... -
Chinese Professional Type A Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.











