Manufactur standard Industrial Circuit Breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
Manufacturer for Residual Circuit Current Breaker - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
China wholesale 1p 2p 3p 4p Mcb - C45 1P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P... -
PriceList for 16 Amp Circuit Breaker - HVS MCB circuit breaker – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
Manufacturer for Residual Circuit Current Breaker - DAL10-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter valu Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A),... -
Chinese Professional Type A Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope... -
2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br... -
2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br... -
2018 wholesale price Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Hot sale Two Pole Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
High definition 32 Amp Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1... -
High Quality Elcb Mccb - DAM1L-125 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...