-
Short Lead Time for 4 Pole Mccb Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
New Delivery for 60a Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P... -
Free sample for Automatic Circuit Breaker - Micro changeover switch – DaDa
l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen... -
OEM/ODM Supplier Solar Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa
Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t... -
Manufacturing Companies for 15 Amp Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
Special Price for Circuit Breaker Switch - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
Hot New Products Contact Auxiliary – Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ... -
New Arrival China Industrial circuit breaker – DAM2 Moulded Case Circuit Breaker – DaDa
Application DAM2 series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2 circuit ... -
Top Suppliers 4 Pole Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P... -
Manufacturer for Residual Circuit Current Breaker - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa
Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel... -
China Cheap price Thermal Adjustable circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa
Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig...










