China Cheap price Thermal Adjustable circuit breaker - DAM3-1000 MCCB Molded Case Circuit Breaker – DaDa
Overview The rated current of DAM3-1000 molded case circuit breaker can up to 690A, it’s generally used in the power distribution circuit to distribute power and protect circuit and power equipment from overloaded, short circuit, under voltage failure damage, in which alternating current 50-60Hz, rated direct-current 1000A. Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings. Electrical Parameters of DAM3... -
Factory Price 3 Amp Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
Hot New Products Tp Mccb - DAM7 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Type Number of poles Rated current in(A) Ultimate short circuit breaking capacity(KA),Icu DC AC50/60HZ 125V 250v 220/240V 380V 415V 440/460V 480/500v 600v ABE52b 2 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE53b 3 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE54b 4 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE102b 2 10,15,20,30,40,50,60,75,100 10 5 25 14 10 10 7.5... -
-
New Arrival China 10 Amp Mini Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
2018 wholesale price 63 Amp Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting. -
China OEM Three Phase Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co... -
Professional China Id Rccb - DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
High definition 32 Amp Circuit Breaker - Micro changeover switch – DaDa
l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen... -
China Cheap price Elctronic Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Good Quality Residual Current Circuit Breaker With Overcurrent Protection - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H... -
Manufacturer for Residual Circuit Current Breaker - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa
Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel...