2018 High quality Contactor Switch Ac - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3) -
OEM Factory for 6 Amp Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P... -
-
Renewable Design for Time Delay Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ... -
2018 wholesale price Motor Protection Circuit – GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
OEM Factory for 6 Amp Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/... -
2018 China New Design Main Mccb - DAM7 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Type Number of poles Rated current in(A) Ultimate short circuit breaking capacity(KA),Icu DC AC50/60HZ 125V 250v 220/240V 380V 415V 440/460V 480/500v 600v ABE52b 2 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE53b 3 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE54b 4 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE102b 2 10,15,20,30,40,50,60,75,100 10 5 25 14 10 10 7.5... -
Hot Sale for Safety Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
factory Outlets for 100a Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa
Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co... -
High Quality Elcb Mccb - DAM1L-630 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
Introduction DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology. Protected moulded case type circuit breaker. The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distrib... -
Professional China Distribution Box Plastic - SHPN Series Waterproof Distribution Box – DaDa
Outline Dimension Packing Information SHPN waterproof distribution box Carton L*W*H(cm) (PCS/CTN) G.W.(kgs/ctn) N.W.(kgs/ctn) SH4PN 4 way 510*355*450 30 10 9 SH6PN 6 way 540*355*430 20 16 15 SH9PN 9 way 540*425*465 20 19 18 SH12PN 12 way 595*485*575 20 27 26 SH18PN 18 way 595*485*405 10 19 18 SH24PN 24 way -
2018 wholesale price 63 Amp Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope...