-
2018 Latest Design Electric Circuit Breaker - Micro changeover switch – DaDa
l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen... -
Top Suppliers 4 Pole Circuit Breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
High Quality Ac Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3) -
Chinese Professional Mccb 1000 Amp - DAM1 630 Series MCCB ABB ISOMAX – DaDa
Advantages •Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ontan installation panel. •With the help of special clamp 125 and 160 units can be installed onta DIN-rail. •Weight and dim... -
Good Quality Moulded Case Circuit Breaker - DAM1-125 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t... -
Bottom price 60 Amp Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
Good Quality Shunt Release - Plug-In And Draw-Out Device – DaDa
CM 1 Plug-in Version Accessory Type Scope of application Specification and quantities Contact pin Arc-isolation plate and quantities Plug-in version install using hexagonal screw and quantities Circuit breaker install using screw and quantities Contact pin fixed screw and quantities User bind the board install using screw and quantities 63 Type plug-in version CM1-63,NM1-63,CDM1-63,TM30-63 1 6 4 4-M6X23 4-M3X18 6-M5copper nut 6-M5X10 100 Type plug-... -
Factory source House Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa
Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t... -
2018 High quality Auxiliary Contact - Auxiliary contact Alarm contact – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat... -
factory Outlets for 100a Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co... -
OEM/ODM China 3 Amp Mini Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ... -
Factory Free sample Low Voltage Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...