product

  • Best Price on Type C Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Best Price on Type C Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • Cheapest Price Magnetic Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Cheapest Price Magnetic Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ...
  • Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Good Quality Thermal Shrink Busbar Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    Good Quality Thermal Shrink Busbar Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product...
  • Well-designed Circuit Breaker Protection - DAB7 L7 Mini circuit breaker – DaDa

    Well-designed Circuit Breaker Protection - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Wholesale Price China 5 Amp Mini Circuit Breaker - C45 4P  Miniature Circuit Breaker – DaDa

    Wholesale Price China 5 Amp Mini Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • Quality Inspection for Motorized Circuit Breaker – C45 4P  Miniature Circuit Breaker – DaDa

    Quality Inspection for Motorized Circuit Breaker – C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • China wholesale thermal overload circuit breaker - DAM2 Moulded Case Circuit Breaker – DaDa

    China wholesale thermal overload circuit breaker - DAM2 Moulded Case Circuit Breaker – DaDa

    Application DAM2  series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2 circuit ...
  • Fast delivery Marine Circuit Breaker - DAB5 MCB – DaDa

    Fast delivery Marine Circuit Breaker - DAB5 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Special Design for 20 Amp Mini Circuit Breaker - DAB6  MCB – DaDa

    Special Design for 20 Amp Mini Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Factory wholesale 150 Amp Circuit Breaker - HVS  MCB  with window – DaDa

    Factory wholesale 150 Amp Circuit Breaker - HVS MCB with window – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • 2018 High quality Motor Rated Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    2018 High quality Motor Rated Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...