product

  • Manufacturer for 45a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Manufacturer for 45a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • Wholesale Price China Rcbo 1 Pole – RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Wholesale Price China Rcbo 1 Pole – RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • Fast delivery Marine Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Fast delivery Marine Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • Professional China A Type Ac Type Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Professional China A Type Ac Type Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • Hot New Products Tp Mccb - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    Hot New Products Tp Mccb - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    AF 50AF 100AF 250AF Type N-type N-type N-type Type and Pole 3-Pole ABN53C ABN103C ABN203C Rated current,In A 15.20.30.40.50 15.20.30.40.50.60.75.100 100.125.150.175.200.225.250 Rated operational voltage,Ue AC(V) 690 690 690 DC(V) 500 500 500 Rated insulation voltage,Ui V 750 750 750 Rated impulse withstand voltage,Uimp kV 8 8 8 Rated short-circuit breaking capacity(Icu) kA (Sym),KSC8321,IEC 60947-2     AC 690V ...
  • Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Professional China Motor Start Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    Professional China Motor Start Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Free sample for Automatic Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Free sample for Automatic Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...
  • PriceList for Double Pole Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    PriceList for Double Pole Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...
  • Professional China 10KA MCB - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Professional China 10KA MCB - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Factory Cheap Hot 10 Amp Mini Fuse Circuit Breaker - DAB6  MCB – DaDa

    Factory Cheap Hot 10 Amp Mini Fuse Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...