product

  • 2018 wholesale price Under Voltage Release - Auxiliary contact Alarm contact – DaDa

    2018 wholesale price Under Voltage Release - Auxiliary contact Alarm contact – DaDa

    Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of  circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position     Explanation Us1 is auxiliary power Us2 is alarm power Open position     Explanat...
  • High Quality Ac Contactor - Contactor – DaDa

    High Quality Ac Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Hot sale Two Pole Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

    Hot sale Two Pole Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E...
  • China wholesale Auxiliary Contact+Alarm Contact - Alarm Contacts – DaDa

    China wholesale Auxiliary Contact+Alarm Contact - Alarm Contacts – DaDa

    Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of  circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position     Open position              DAM1-125/160BC       DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A           DZ20-225BC        DZ20-225A               ...
  • Hot New Products Contact Auxiliary – Electrical Operating Mechanism (Motor) – DaDa

    Hot New Products Contact Auxiliary – Electrical Operating Mechanism (Motor) – DaDa

    DAM1(ABB) Electrical Operating Mechanism The electrical operating mechanism is available remote close of MCCB The types of electrical operating mechanism are shown in table 2 Types Of Electrical Operating Mechanism:   Table 2 Rated current of frame size Inm Types of electrical Operating Mechanism CD1 CD2 CD3 CD 63A - CD2-63 - - 100A - CD2-100 - - 160A - CD2-160 - - 250A CD1-250 CD2-250 - CD-250 400A CD1-400 - - CD-400...
  • Professional China Leakage circuit breaker - DAM1L-125 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    Professional China Leakage circuit breaker - DAM1L-125 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • Chinese wholesale Mcb Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

    Chinese wholesale Mcb Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E...
  • Good User Reputation for 125 Amp Circuit Breaker - DAB6  MCB – DaDa

    Good User Reputation for 125 Amp Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Good Quality Mini Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

    Good Quality Mini Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E...
  • OEM/ODM Manufacturer 3 Pole Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    OEM/ODM Manufacturer 3 Pole Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...
  • Hot-selling Thermal Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Hot-selling Thermal Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • Wholesale Micro Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Wholesale Micro Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...