  • Hot New Products 2 Pole Rccb – DAL2-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Hot New Products 2 Pole Rccb – DAL2-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • 2018 Good Quality House circuit breaker - HVS  Isolator – DaDa

    2018 Good Quality House circuit breaker - HVS Isolator – DaDa

    Low Watt Loss Low power loss. Longer Electrical Life DesIgned for better and longer electrical life. Value for Money Assured reliability and service makes it value for money. Low power consumption, thus cost effective & energy saving Consumes less power, thus cost effective and energy saving.
  • Good Quality Shunt Release - Under Voltage Release – DaDa

    Good Quality Shunt Release - Under Voltage Release – DaDa

    Application The under voltage is intended for under voltage protection of circuit and electric equipment. Release uniterrupted duty. Characteristics of under voltage release: Ue(V)Rated operation voltage AC380 AC220 DC110 DC220 Operation voltage (0.35-0.7)) x Ue Ensured closing voltage (0.85-1.1)) x Ue Ensured non closing voltage ≤0.35 Ue Power loss 10VA 4W Wiring Diagram Of Under Voltagerelease Us- Control power P1,P2- Terminal number                ...
  • China wholesale Motor Circuit Protector - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    China wholesale Motor Circuit Protector - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • China wholesale thermal overload circuit breaker - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    China wholesale thermal overload circuit breaker - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    AF 50AF 100AF 250AF Type N-type N-type N-type Type and Pole 3-Pole ABN53C ABN103C ABN203C Rated current,In A 15.20.30.40.50 15.20.30.40.50.60.75.100 100.125.150.175.200.225.250 Rated operational voltage,Ue AC(V) 690 690 690 DC(V) 500 500 500 Rated insulation voltage,Ui V 750 750 750 Rated impulse withstand voltage,Uimp kV 8 8 8 Rated short-circuit breaking capacity(Icu) kA (Sym),KSC8321,IEC 60947-2     AC 690V ...
  • Short Lead Time for 4 Pole Mccb Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Short Lead Time for 4 Pole Mccb Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • Fixed Competitive Price 10a Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    Fixed Competitive Price 10a Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • Professional China Leakage circuit breaker - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    Professional China Leakage circuit breaker - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • Good Quality Mini Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Good Quality Mini Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ...
  • Europe style for Power Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

    Europe style for Power Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • 2018 Good Quality Mccb 100 - DAM11 Series Moulded-case Circuit Breaker – DaDa

    2018 Good Quality Mccb 100 - DAM11 Series Moulded-case Circuit Breaker – DaDa

    Product overview DAM11, DAM11LY, DAM11RT, DAM11E and DAM11EY series of circuit breakers are new upgraded circuit breakers researched and developed by the company combined with the advantages of similar international products and demand of domestic and international markets. With insulation voltage up to 1000V, the circuit breaker is applicable for distribution systems of AC50Hz, rated working voltage 690V and rated working current from 10A to 800A, used to distribute electric power energ...
  • Competitive Price for 400 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Competitive Price for 400 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...