product

  • Best quality Adjustable Circuit Breaker - HVS  MCB  circuit breaker – DaDa

    Best quality Adjustable Circuit Breaker - HVS MCB circuit breaker – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • Best quality Adjustable Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Best quality Adjustable Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ...
  • 2018 Good Quality Rccb Protection - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa

    2018 Good Quality Rccb Protection - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • Factory wholesale 150 Amp Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

    Factory wholesale 150 Amp Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Factory wholesale 150 Amp Circuit Breaker - C65 MCB – DaDa

    Factory wholesale 150 Amp Circuit Breaker - C65 MCB – DaDa

    ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am...
  • Low MOQ for 25a Circuit Breaker - HVS  Isolator – DaDa

    Low MOQ for 25a Circuit Breaker - HVS Isolator – DaDa

    Low Watt Loss Low power loss. Longer Electrical Life DesIgned for better and longer electrical life. Value for Money Assured reliability and service makes it value for money. Low power consumption, thus cost effective & energy saving Consumes less power, thus cost effective and energy saving.
  • 2018 Good Quality Ac Motor Contactor - Contactor – DaDa

    2018 Good Quality Ac Motor Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Good Quality Residual Current Circuit Breaker - DAL10-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Good Quality Residual Current Circuit Breaker - DAL10-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter valu Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A),...
  • 2018 High quality Modular Power Distribution Box – Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base – DaDa

    2018 High quality Modular Power Distribution Box – Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base – DaDa

    Model Description TXM: series of distribution box Numbers of circuit:4,6,8,12,15,18,24,36 M:means Open mounted R:means Concealed mounted A:the cover is transparent P: plastic base Parameters ▪ Rated current: 63 [A] ▪ Short-circuit making current: 10 (KA) ▪ Shell protection grade: IP40; ▪ Shell material: ABS polymeric carbon ▪ Color: White ▪ Face covering: Transparent Outline Dimension    Surface    Flush   TXM distribution box(plastic)      Carton L*W*H(cm)   (PCS/CTN) G.W....
  • High Quality Rcbo Circuit Breaker - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    High Quality Rcbo Circuit Breaker - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope...
  • Low MOQ for 25a Circuit Breaker - DAB5 series Miniature Circuit breaker(MCB) – DaDa

    Low MOQ for 25a Circuit Breaker - DAB5 series Miniature Circuit breaker(MCB) – DaDa

    >> Introduction DAB5-63  are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker DAB5-63 are recommended for use in electrical distribution panels of residential and public bui...
  • Good Wholesale Vendors Automotive Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

    Good Wholesale Vendors Automotive Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...