  • China wholesale Dc Contactor - Contactor – DaDa

    China wholesale Dc Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Good Quality Residual Current Circuit Breaker With Overcurrent Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Good Quality Residual Current Circuit Breaker With Overcurrent Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • Wholesale Price China Rcbo 1 Pole – DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Wholesale Price China Rcbo 1 Pole – DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
  • Personlized Products 200a Circuit Breaker - C65 MCB – DaDa

    Personlized Products 200a Circuit Breaker - C65 MCB – DaDa

    ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am...
  • Wholesale Micro Circuit Breaker - HVS  Isolator – DaDa

    Wholesale Micro Circuit Breaker - HVS Isolator – DaDa

    Low Watt Loss Low power loss. Longer Electrical Life DesIgned for better and longer electrical life. Value for Money Assured reliability and service makes it value for money. Low power consumption, thus cost effective & energy saving Consumes less power, thus cost effective and energy saving.
  • China wholesale Electronic Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    China wholesale Electronic Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • New Delivery for 60a Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa

    New Delivery for 60a Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
  • Manufacturer for Residual Circuit Current Breaker - DAF360 Series Residual Current Circuit Breakers – DaDa

    Manufacturer for Residual Circuit Current Breaker - DAF360 Series Residual Current Circuit Breakers – DaDa

    Introduction      If a ground fault current is detected by the DAF360 residual current circuit breaker, it will compare it to the ground leakage release current value and the circuit breaker will immediately break the circuit if the former is greater than the latter.Circuit breakers can connect ground systems in order to protect the charged body from indirect contact. It also functions to direct contact charged body additional protection if the rated residual current value is greater than ...
  • Cheap price 25 Amp Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa

    Cheap price 25 Amp Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa

    >> Introduction BA47-29  are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui...
  • China Cheap price Thermal Adjustable circuit breaker - DAM3-1000 MCCB Molded Case Circuit Breaker – DaDa

    China Cheap price Thermal Adjustable circuit breaker - DAM3-1000 MCCB Molded Case Circuit Breaker – DaDa

    Overview The rated current of DAM3-1000 molded case circuit breaker can up to 690A, it’s generally used in the power distribution circuit to distribute power and protect circuit and power equipment from overloaded, short circuit, under voltage failure damage, in which alternating current 50-60Hz, rated direct-current 1000A. Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings. Electrical Parameters of DAM3...
  • China Cheap price Motor Protection Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    China Cheap price Motor Protection Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Hot New Products Tp Mccb - DAM1 800 MCCB Moulded Case Circuit Breaker – DaDa

    Hot New Products Tp Mccb - DAM1 800 MCCB Moulded Case Circuit Breaker – DaDa

    Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing...