    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • OEM/ODM Factory 100 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    OEM/ODM Factory 100 Amp Circuit Breaker - MCB Under Voltage Release – DaDa

    Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
  • 2018 High quality 25 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    2018 High quality 25 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
  • 2018 High quality Electromagnetic Rccb - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa

    2018 High quality Electromagnetic Rccb - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa

    Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel...
  • Professional China Id Rccb - RTF1L-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Professional China Id Rccb - RTF1L-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Advantage Specification Frame class 63A Rated working voltage 240/415V Rated frequency 50/60Hz Rated working current 16, 20, 25, 32, 40, 50, 63A Rated residual operating current 0.03, 0.1, 0.3A Rated residual un-operating current 0.015, 0.05, 0.15A Sensibility AC Type, A Type, B Type Maximum operating time IΔn t≤0.1s, 5IΔn t≤0.04 Rated making and breaking capacity In≤50A 500A, In=63A 630A Limiting value of un-operating current 6In Rated limiting short-circuit curre...
  • Hot Selling for Main Switch Circuit Breaker - DAB7-63 DC miniature Circuit Breaker – DaDa
  • China Cheap price 6 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    China Cheap price 6 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
  • Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of  circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position     Open position              DAM1-125/160BC       DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A           DZ20-225BC        DZ20-225A               ...
  • High Quality Electronic Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa

    High Quality Electronic Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa

    Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
  • 18 Years Factory Short Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    18 Years Factory Short Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Hot New Products Contact Auxiliary – Alarm Contacts – DaDa

    Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of  circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position     Open position              DAM1-125/160BC       DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A           DZ20-225BC        DZ20-225A               ...
  • Hot New Products 10a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Hot New Products 10a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...