product

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa


Product Detail

Product Tags

Related Video

Feedback (2)

We have been ready to share our knowledge of advertising and marketing worldwide and recommend you suitable products and solutions at most competitive price ranges. So Profi Tools supply you best benefit of money and we're ready to create with each other with Mccb, Rccb, 10a Rcbo, We always welcome new and old customers presents us with valuable advice and proposals for cooperation, let us grow and develop together, and to contribute to our community and staff!
2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa Detail:

Under normal conditions,It can also be used for infrequent switching of lines.
This circuit breaker also has the following protection:
• It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.
• Provide protection against the danger of increasing ground voltage due to insulation damage;
• Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.
• Circuit breakers with rated current of 500A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.
DAM1L series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.

This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines
Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.

Advantages

• Range:10A to 500A(AC)
• integral structure, small volume, high breaking capacity, safe and reliable.
• Adjustable magnetic setting(0.8-1times)In.
• Push to trip button provision.
• Separate main and arcing contacts
• Can be adjusted the residual action current or disconnection time according to the actual use.
• Strong anti-interference ability.
• Wide range of accessories.

The working power of the residual current protection circuit of this series of circuit breakers is supplied by the multi-phase power supply (the working power of the protection circuit of early products is supplied by the single-phase power supply)the residual current protection circuit of the device can still operate normally.When the operating power voltage of the circuit breaker’s residual current protection circuit is reduced to 50V, the circuit breaker’s residual current protection circuit can still work normally.(I coherence n=30mA)

This series of circuit breakers are classified into B type (i.e., basic breaking capacity) (Inm less than 100), S type (i.e., standard breaking capacity) and H type (i.e High score breaking capacity (Inm > 160) can be used in different situations.

The main circuit of a circuit breaker is connected in many ways:
-Piston front connection
-Terminal extension plate front connection
-The screw connection at the rear of the piston plate

Earth-Leakage Circuit Breakers

DAM1L series Earth Leakage protection circuit breaker (ELCB)3462

Residual current circuit breaker basic parameters

COSφ

 

Rated current of remnant motion I△n

(mA)

 

 

Rated current of remnant no-motion I△no

 (mA)

 

Max-Breaking time (S)

0.2

100,300,500

50,150,250

0.05,0.5, 0.8

Rated residual operating current(mA)

Rated no tripping current value.I△no(mA)

Residual current value range.(mA)0.5x(I△n+I△no)±0.2I△n

30

15mA

18mA-27mA

100

50mA

60mA-90mA

300

150mA

180mA-270mA

500

250mA

300mA-450mA

1000

500mA

600mA-900mA

Earth-Leakage Circuit Breakers(ELCB)

 DAM1L series Earth Leakage protection circuit breaker (ELCB)3967 

 DAM1L series Earth Leakage protection circuit breaker (ELCB)3969

Model

DAM1-125L

DAM1-160L

Breaking Capacity Code

B

N

S

B

N

S

Rated Current of Frame size- Inm    (A)

125A

160A

Rated Current-In(40,50 or 55℃)   (A)

10 – 12,5 – 16 – 20 – 25 – 32(30) – 40 – 50 – 63(60) – 80 – 100 – 125A

10- 12,5-16-20 – 25 – 32 – 40 - 50 – 63 – 80 – 100 -125 – 160(150)A

Ui (V)

690V

690V

Ue (V)

400V

400/415V

Number of Pole

4P

4P

Icu (KA)

25

35

50

25

35

50

Ics(KA)

12.5

17.5

37.5

12.5

26.25

37.5

Icm(peak)/cos ф (KA)

40/0.3

73.5/0.25

105/0.25

41/0.3

73.5/0.25

110/0.25

(I△m)KA/cosф

9/0.5

19/0.5

Residual current threshold(mA)

100-300-500

100-300-500

Time delay(ms)

50-500-800

50-500-800

Uimp (V)

10000

8000

Dielectric Propery (V)

2500

3000

lonization distance  (mm)

≤30/0

≤30/0

Endurance

Total Cycles

8000

8000

Electrical Life

1000

1000

Mechanical Life

7000

7000

Category (EN 60947-2/IEC 60947-2)

Main circuit

A/0

A/0

Auxiliary circuit

AC-15

AC-15

Under Voltage Release

Shunt Release

Auxiliary Contact

Alarm Contact

Auxiliary Contact and Alarm Contact

Handle Operation Mechanism

Electrical Operastion Mechanism

Terminal cover    

Phase seperator    

 DAM1L series Earth Leakage protection circuit breaker (ELCB)5103

W (mm)

3P

-

-

4P

101

120

L (mm)

3P

-

-

4P

155

120

H (mm)

3P

-

-

4P

70

70

Weight

Fixed version 3P/4P

-

-

Plug-in version 3P/4P

-

-

Draw out version 3P/4P

-

-

Earth-Leakage Circuit Breakers(ELCB)

DAM1L series Earth Leakage protection circuit breaker (ELCB)5319

   DAM1L series Earth Leakage protection circuit breaker (ELCB)5321 

Model

DAM1-250L

DAM1-400L

Breaking Capacity Code

N

S

H

G

N

S

H

G

Rated Current of Frame size- Inm                       (A)

250A

400A

Rated Current-In(40,50 or 55℃)                   (A)

63 – 80-100-125 – 160(180) - 200(225) – 250(320)A

250 – 315 (350)- 400 – 500A

Ui (V)

690V

690V

Ue (V)

400/415V

400/415V

Number of Pole

4P

4P

Icu (KA)

35

50

65

85

35

50

70

85

Ics(KA)

26.25

37.5

48.75

51

26.25

37.5

52.5

52.5

Icm(peak)/cos ф (KA)

77/0.25

114/0.25

143/0.2

178/0.2

70/0.25

110/0.25

154/0.2

187/0.2

(I△m)KA/cosф

12/0.3

19/0.5

Residual current threshold(mA)

100-300-500

100-300-500

Time delay(ms)

50-500-800

50-500-800

Uimp (V)

8000

8000

Dielectric Propery (V)

3000

3000

lonization distance (mm) ≤30/0※ ≤60/0※
Endurance

Total Cycles

8000

5000

Electrical Life

1000

1000

Mechanical Life

7000

4000

Category (EN 60947-2/IEC 60947-2)

Main circuit

A/B

A/B

Auxiliary circuit

AC-15

AC-15

Under Voltage Release

Shunt Release

Auxiliary Contact

Alarm Contact

Auxiliary Contact and Alarm Contact

Handle Operation Mechanism

Electrical Operation Mechanism

Terminal cover    

Phase seperator    

 DAM1L series Earth Leakage protection circuit breaker (ELCB)6467

W (mm)

3P

-

-

4P

140

184

L (mm)

3P

-

-

4P

210

254

H (mm)

3P

-

-

4P

103.5

103.5

Weight

Fixed version 3P/4P

-

41.5/5.5

5.1/7.1

Plug-in version 3P/4P

-

4.6/6

6.5/8.5

Draw out version 3P/4P

-

5/6.4

6.5/8.7

• Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
• Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)


Product detail pictures:

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa detail pictures

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa detail pictures

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa detail pictures

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa detail pictures

2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for 2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa , The product will supply to all over the world, such as: Slovenia, Cannes, Suriname, When It produced, it making use of the world's major method for reliable operation, a low failure price, it appropriate for Jeddah shoppers choice. Our enterprise. s situated inside the national civilized cities, the website traffic is very hassle-free, unique geographical and financial circumstances. We pursue a "people-oriented, meticulous manufacturing, brainstorm, make brilliant" company philosophy. Strict good quality management, fantastic service, affordable cost in Jeddah is our stand around the premise of competitors. If needed, welcome to make contact with us by our web page or phone consultation, we will be delighted to serve you.
  • This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Heloise from Israel - 2018.06.18 17:25
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Elaine from Benin - 2018.11.28 16:25
    Write your message here and send it to us